Introduction to the iSMA Configurator Software
The configurable I/O modules provide universal inputs that support temperature, analog, resistance and binary in a single module. For applications not requiring universal inputs there are modules with discrete inputs that support contact closure and retentive pulse counting at 100Hz. Additional modules supply a mix of universal and/or discrete inputs with relay outputs and analog outputs. A single module supports BACnet MS/TP or Modbus RTU/ASCII with a simple dip switch selection.
The modules are housed in a compact UL approved self-extinguishing plastic enclosure, rated for operation in -10°C to +50°C (14°F to 122°F) environments and DIN rail or panel mounted typically in a control enclosure. All modules use half-wave rectified low voltage power supply that allows for sharing of power with other 24 VAC/VDC devices. All IP version modules are equipped with a built-in Modbus TCP/IP for RS485 gateway which allows for establishing a connection with RS485, additional I/O modules, or 3rd party devices.

The iSMA Configurator has been designed to perform configuration, firmware updates and diagnostics on the configurable I/O. The free downloadable software provides communication with the use of USB, BACnet MS/TP, Modbus RTU, BACnet IP or Modbus TCP. It allows monitoring the device's operating parameters, remote change of I/O module output states and input modes. This simple and intuitive to use software is the convenient tool for every configurable I/O user. This software is intended for Windows operating system and can be run on Windows 7, 8 or 10. There is no need to install any additional software or drivers to run iSMA Configurator.
| Model | UI | DI | AO | DO | TO | HOA |
| iSMA-B-8I-IP | 8 | |||||
| iSMA-B-8U-IP | 8 | |||||
| iSMA-B-4I4O-H-IP | 4 | 4* | Yes | |||
| iSMA-B-4U4O-H-IP | 4 | 4* | Yes | |||
| iSMA-B-4U4A-H-IP | 4 | 4 | Yes | |||
| iSMA-B-4O-H-IP | 4** | Yes | ||||
| iSMA-B-4TO-H-IP | 4 | Yes | ||||
| iSMA-B-MIX18-IP | 5 | 5 | 4 | 4* | ||
| iSMA-B-MIX38-IP | 8 | 12 | 6 | 12* |
UI = Voltage/Current/Resistive/Dry Contact
DI = Dry Contact/Fast pulse counter (100 Hz)
AO = Analog Out 10V, 20 mA max/PWM
DO* = (NO) 3A @ 24 VAC/30 VDC
DO** = (NO/NC) 8A @ 24 VAC/30 VDC
HOA = Hand-Off-Auto-Switch
iSMA-B-8I-IP provides 8 Digital Inputs (DI) for Dry contact inputs and Fast pulse counter up to 100 Hz that can be saved in EEPROM memory.
iSMA-B-8U-IP provides 8 Universal Inputs (UI). All Universal Inputs have 12-bit or 16-bit resolution which supports the following types of inputs:
iSMA-B-4O-H-IP provides 4 relay (NC/NO) contacts rated max. 8 A @ 24 VAC/30 VDC with Hand Off Auto switch.
iSMA-B-4TO-H-IP provides 4 triac outputs rated 0.5 A @ 24 VAC with Hand Off Auto switch.
iSMA-B-4I4O-H-IP provides:
iSMA-B-4U4O-H-IP provides:
iSMA-B-4U4A-H-IP provides:
iSMA-B-MIX18-IP provides:
iSMA-B-MIX38-IP provides:
IP I/O Module with BACnet/IP and Modbus TCP (with built in Modbus Gateway to RS485) |
|||
| Model | Description | ||
| iSMA-B-8I-IP | 8DI - with BACnet/IP and Modbus TCP (plus Gateway) | $261 | |
| iSMA-B-8U-IP | 8UI - with BACnet/IP and Modbus TCP (plus Gateway) | $341 | |
| iSMA-B-4I4O-H-IP | 4DI and 4DO with HOA - with BACnet/IP and Modbus TCP (plus Gateway) | $313 | |
| iSMA-B-4U4O-H-IP | 4UI and 4DO with HOA - with BACnet/IP and Modbus TCP (plus Gateway) | $341 | |
| iSMA-B-4U4A-H-IP | 4UI and 4AO with hand operation - with BACnet/IP and Modbus TCP (plus Gateway) s | $351 | |
| iSMA-B-4O-H-IP | 4DO relay NC/NO 8 A @ 30V AC or DC with HOA - with BACnet/IP and Modbus TCP (plus Gateway) | $313 | |
| iSMA-B-4TO-H-IP | 4TO triac outputs- .5 A @ 30 V AC with HOA - with BACnet/IP and Modbus TCP (plus Gateway) | $313 | |
| iSMA-B-MIX18-IP | 5DI, 5UI, 4AO, 4DO - with BACnet/IP and Modbus TCP (plus Gateway) | $444 | |
| iSMA-B-MIX38-IP | 12DI, 8UI, 6AO, 12DO - with BACnet/IP and Modbus TCP (plus Gateway) | $573 | |
Accessories |
|||
| Model | Description | ||
| AI-XFMR | Wall-mount plug-in transformer 120 VAC (nom) input/24 VAC (nom) output (details...) | $43 | |
| AI-XFMR-E | Wall-mount plug-in transformer 230 VAC (nom) input/24 VAC (nom) output (details...) | $60 | |
| MDR-20-24 | 24VDC 20W DIN RAIL POWER SUPPLY (details...) | $44 | |
| MDR-40-24 | 24VDC 40W DIN RAIL POWER SUPPLY (details...) | $54 | |
| SDR-75-24 | 24VDC 75W DIN RAIL POWER SUPPLY (details...) | $99 | |
Spare Terminal Strip Connectors |
|||
| Model | Description | ||
| iSMA-B-8I-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-8I / ISMA-B-8I-IP module types. | $19 | |
| iSMA-B-8U-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: ISMA-B-8U / iSMA-B-8U-IP module types. | $19 | |
| ISMA-B-4I4O-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4I4O-H / iSMA-B-4I4O-H-IP module types. | $19 | |
| ISMA-B-4U4O-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4U4O-H / iSMA-B-4U4O-H-IP module types. | $19 | |
| ISMA-B-4U4A-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4U4A-H / iSMA-B-4U4A-H-IP module types. | $19 | |
| ISMA-B-4O-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4O-H / iSMA-B-4O-H-IP module types. | $19 | |
| ISMA-B-4TO-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4TO-H / iSMA-B-4TO-H-IP module types. | $19 | |
| iSMA-B-MIX18-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-MIX18 / iSMA-B-MIX18-IP module types. | $25 | |
| iSMA-B-MIX38-TB | Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-MIX38 / iSMA-B-MIX38-IP module types. | $34 | |
Related Products |
|||
| Model | Description | ||
| EISK5-100T | Five-port 10BASE-T/100BASE-TX Skorpion switch, DIN-rail mount | $123 | |
| EISK8-100T | Eight-port 10BASE-T/100BASE-TX Skorpion switch, DIN-rail mount | $186 | |
| EISK16-100T | Sixteen-port 10BASE-T/100BASE-TX Skorpion switch, DIN-rail mount | $351 | |
| BASGSX-M1 | BASgatewaySX Modbus to BACnet Gateway DIN-rail Mount with SSL | $528 | |
| BASGSX-M1/P | BASgatewaySX Modbus to BACnet Gateway Panel Mount with SSL | $528 | |