BASautomation Legacy Products

BASautomation

The following items are no longer available. Replacement information, data sheets, installation guides are available on the product pages.

BAScontrol20

The BAScontrol20 is a 20-point unitary controller which supports BACnet/IP and Sedona using a single Ethernet connection. The controller complies with the B-ASC device profile having a convenient mix of 8 universal inputs, 4 binary inputs, 4 analog outputs and either four relay outputs or four triac outputs for floating controllers. The unit has 48 web components which link Sedona wiresheet readable/writeable data to web pages, and 24 virtual points which link Sedona wiresheet readable/writeable data to a BACnet client.

BAScontrol22

The BAScontrol22 is a 22-point unitary controller which supports BACnet/IP and Sedona using a 2-port Ethernet switch connection. The controller complies with the B-ASC device profile having a convenient mix of 8 universal inputs, 4 binary inputs, 4 analog outputs and 6 relay outputs. The unit has 48 web components which link Sedona wiresheet readable/writeable data to web pages, and 24 virtual points which link Sedona wiresheet readable/writeable data to a BACnet client.

BAScontrol22C

The BAScontrol22C is a BACnet/IP server that also has BACnet/IP client capability allowing the user to read and/or write points served up by devices on the BACnet internetwork. Like the BAScontrol22, the BAScontrol22C is a 22-point unitary controller which supports BACnet/IP and Sedona using a 2-port Ethernet switch connection. The controller complies with the B-ASC device profile having a convenient mix of 8 universal inputs, 4 binary inputs, 4 analog outputs and 6 relay outputs. The unit has 48 web components which link Sedona wiresheet readable/writeable data to web pages, and 24 virtual points which link Sedona wiresheet readable/writeable data to a BACnet client.

BASgatewayLX

To make Modbus devices appear as individual BACnet devices a BASgatewayLX is used. The BASgatewayLX supports up to 100 Modbus serial devices with each device appearing as an individual BACnet device. Modbus device profiles for common Modbus devices are available from Contemporary Controls and custom device profiles are created upon request, free of charge.

BASPI-SYS

Raspberry Pi with BASpi 6UI/6 Relay

BASremote

The BASremote is versatile in that it is both a controller and gateway. Up to 63 half-load Modbus serial devices can be connected to the BASremote. Modbus device profiles for common Modbus devices are available from Contemporary Controls.

BASremote PoE (BASR-8M/P)

BASremote I/O Master PoE 6 Universal 2 Relay I/O

BASrouterLX

The BASrouterLX is a high performance router used to route messages between BACnet/IP, BACnet Ethernet and BACnet MS/TP networks. It supports 50 BBMD entries and incorporates a more powerful processor and memory. DIN-rail mounted unit is used for fixed installations.