At AHR Expo 2019 in Atlanta, be sure to stop by booth C5218 to see our suite of new BACnet-compliant and BTL Listed products. We have several new products that we're excited to show off at AHR 2019, along with our popular suite of BASautomation products that provide open solutions when implementing networked controls in buildings.
The BAScontrol Open Control Series utilizes BACnet/IP as an open communications protocol, Sedona for open visual control programming, and the BAScontrol Toolset for unrestricted use in program development and archiving. Ideal for unitary control of air-handlers (AHUs), fan coils (FCUs), and rooftop units (RTUs), these controllers are freely-programmable and customizable.
The BASpi BACnet Client Controller turns an already powerful micro PC, Raspberry Pi, into a BACnet client and open Sedona controller. It serves as a mini-supervisor to BACnet/IP server devices over Ethernet or Wi-Fi and BACnet MS/TP devices over EIA-485. Using custom Sedona network variable components, the BCC can initiate read/write commands from its Sedona wire sheet to BACnet/IP or BACnet MS/TP server points on remote devices. Server points need not be Sedona compliant – just BACnet compliant. Any BACnet remote I/O such as Contemporary Controls' Cube I/O can be made into a freely-programmable controller with the addition of the BCC.
With a new suite of wired and wireless routers, plus our RemoveVPN service, customers have multiple solutions for secure remote access. RemoteVPN is an easy, cost-effective remote access solution that allows you to proactively review and communicate with your customers' automation systems—resulting in valuable time and money savings.
The BASrouter has been independently tested and passed industry-standard BACnet testing and is now BTL Listed for both B-RTR and B-BBMD device profiles. The BASrouter 3.0 provides built-in BACnet diagnostic capabilities with visual analytics that include an MS/TP status table, routing status table, network error counts, and traffic statistics. The new features allow the integrator to install robust BACnet networks with rapid troubleshooting capabilities that easily identify network issues.
The BASview3 is a stand-alone, embedded, web-based graphical interface for building automation and process automation systems.
See you in booth C5218! For those of you attending the ControlTrends Awards on Sunday, be sure to stop by and say hello. The ControlTrends Awards will be held January 13 from 6:30PM to 9:30PM at Atlanta's Historic Fox Theatre.