Data Sheet - 902 MHz EnOcean Gateway
Installation Guide - 902 MHz EnOcean Gateway
User Manual - 902 MHz EnOcean Gateway
Spec Sheet - 902 MHz Stick Antenna
Spec Sheet - EnOcean Cable Antenna
Data Sheet - 868 MHz EnOcean Gateway
Installation Guide - 868 MHz EnOcean Gateway
User Manual - 868 MHz EnOcean Gateway
Spec Sheet - 868 MHz Stick Antenna
Spec Sheet - EnOcean Cable Antenna
Application Note – EnOcean Gateway Motion Sensors
Application Note – EnOcean Gateway Window Monitoring
Application Note – EnOcean Gateway Wireless Leak Detection
Declaration of Conformity - 868 MHz EnOcean Gateway
Video: EnOcean to BACnet Gateway Product Introduction
Video: Understanding How the Bi-directional EnOcean to BACnet Gateway Functions
Integrate your EnOcean wireless devices to BACnet systems with the Contemporary Controls' bidirectional EnOcean to BACnet Gateway.
The EnOcean to BACnet Gateway provides the systems integrator with a flexible building block when integrating EnOcean wireless devices to BACnet/IP networks or expanding the number of EnOcean points in an existing building automation system. Thanks to our use of virtual routing technology, our gateway allows building automation supervisors to seamlessly discover EnOcean devices via BACnet because each device will appear as separate BACnet-compliant devices. The gateway creates a set of BACnet objects, specific for each EnOcean Equipment Profile (EEP), and decodes the received EnOcean data into standard BACnet objects, such as analog-inputs for temperatures, humidity, light levels, etc. and multistate objects for EnOcean values that represent multiple states, for easy integration to BACnet system — saving the head-end from decoding the transmitted EnOcean data.
The EnOcean to BACnet Gateway provides the ultimate in flexibility. It features EnOcean device discovery with built-in EEP and web-page configuration using a common web browser. There are no external tools required for configuration. This allows EnOcean devices to be easily combined with BACnet devices and supervisors into one automation system.
Using remote commissioning the gateway can configure EnOcean output devices to be controlled by specific input devices. This can save you from the manual linking that requires repeatedly pressing buttons on the EnOcean devices until they are linked and can make installation of EnOcean devices much easier.
All models feature an SMA connector that supports a stick antenna or an antenna with 2 m cable for mounting the antenna outside the control cabinet. Antenna sold separately.
Model BASGE-EN902 uses 902 MHz for the North American market. Model BASGE-EN868 uses 868 MHz for the European and Chinese market.
| Model | Description | ||
| BASGE-EN902 | EnOcean to BACnet Gateway 902 MHz (North American Version) Note: An antenna is required but not included. Be sure to purchase either the BASGE-ANT902 or the BASGE-ANT-2M (listed below). |
$464 | |
| BASGE-EN868 | EnOcean to BACnet Gateway 868 MHz (European Version) Note: An antenna is required but not included. Be sure to purchase either the BASGE-ANT868 or the BASGE-ANT-2M(listed below). |
Visit EMEA Store | |
Antennas |
|||
| Model | Description | ||
| BASGE-ANT902 | EN902 stick antenna (details...) | $32 | |
| BASGE-ANT868 | EN868 stick antenna (details...) | Visit EMEA Store | |
| BASGE-ANT-2M | EnOcean antenna with 2m cable (details...) | $37 | |
Accessories |
|||
| Model | Description | ||
| AI-XFMR | Wall mount plug in transformer 120VAC input/24VAC output (details...) | $43 | |
| AI-XFMR-E | Wall mount plug in transformer 230VAC input/24VAC output (details...) | $60 | |
| MDR-20-24 | 24VDC 20W DIN RAIL POWER SUPPLY (details...) | $44 | |
| MDR-40-24 | 24VDC 40W DIN RAIL POWER SUPPLY (details...) | $54 | |
| SDR-75-24 | 24VDC 75W DIN RAIL POWER SUPPLY (details...) | $99 | |